Exceptionally salt- and water-efficient whole-home cabinet water softener. Up to 30% reduction of salt emissions of a household.
Aquaphor S800 P1 model removes high concentrations of hardness salts, iron and manganese, and as well — hydrogen sulfide in municipal or well water.
Requires up to 30% less salt
The specially designed tank contains extra fine mesh and tightly compacted chlorine-resistant ion-exchange resin with granules 2 times smaller than in classical columns. The tank design extends its` contact with water and boosts overall salt-efficiency.
All-in-1: water softening, iron, manganese & hydrogen sulfide removal
With the same volume of ion-exchange resin, AQUAPHOR S800 provides a larger surface area in contact with water, absence of channel effect, while small granules regenerate faster and more efficiently. As a result — removal of a high concentration of Fe (up to 15 ppm).
KDF85 process media accounts for for hydrogen sulfide filtration.
Up to 5 times less water for regeneration
Regeneration of softener and especially iron removal system is very a water-consuming process for classical systems with columns. The innovative, patented Dual Core Valves of the AQUAPHOR S800 assures long-term trouble-free performance concurrently wasting minimal amount of water.
Aquaphor S800 P1 model removes high concentrations of hardness salts, iron and manganese, and as well — hydrogen sulfide in municipal or well water.
Requires up to 30% less salt
The specially designed tank contains extra fine mesh and tightly compacted chlorine-resistant ion-exchange resin with granules 2 times smaller than in classical columns. The tank design extends its` contact with water and boosts overall salt-efficiency.
All-in-1: water softening, iron, manganese & hydrogen sulfide removal
With the same volume of ion-exchange resin, AQUAPHOR S800 provides a larger surface area in contact with water, absence of channel effect, while small granules regenerate faster and more efficiently. As a result — removal of a high concentration of Fe (up to 15 ppm).
KDF85 process media accounts for for hydrogen sulfide filtration.
Up to 5 times less water for regeneration
Regeneration of softener and especially iron removal system is very a water-consuming process for classical systems with columns. The innovative, patented Dual Core Valves of the AQUAPHOR S800 assures long-term trouble-free performance concurrently wasting minimal amount of water.
Aquaphor S800 P1 suits for
Whole-house water supply
Laundry & Cleaning
Beauty & SPA
MODEL | S800 P1 |
---|---|
Maximum capacity, g | 1 680 |
Maximum compensated hardness, mg/l | 1 380 |
Maximum concentration of dissolved iron and manganese, mg/l* | 12 |
Minimum pH | 6 |
Temperature of water and environment, °C | +5...+38 |
Water pressure, MPa | 0,14–0,7 |
Minimum water flow for backwash, l/min** | 7,6 |
Maximum flow to drain during regeneration, l/min | 9,1 |
Nominal / maximum flow, l / min | 25 / 38 |
Pressure loss at flow 22.7 l/min (6 gpm), MPa*** | 0,1 |
Capacity in HE mode, kg of salt / gram of hardness | 1,1 / 670 |
Capacity in HC mode, kg of salt / gram of hardness | 3,0 / 1406 |
Maximum capacity in AU mode, kg of salt / gram of hardness | 5,4 / 1625 |
Regeneration method | Intelligent, by water meter |
Power options | 12 VAC; 50/60 Hz; 0.015 kWh |
Connection ports (NPT) | 1" (MNPT) |
Minimum drain line diameter, mm (in) | 16 (5/8) |
Filtration tank size (ID × H), mm | 267 × 584 |
Height, cm | 70,6 |
Base, cm | 40,4 × 48,5 |
Gross weight, kg | 43 |
Superfine monodisperse ion exchange resin, l | 23 |
Quartzite, kg | 0,8 |
or KDF85, l | 0,35 |
* Reducing the concentration of iron to 0.3 mg/l and below, manganese - to 0.1 mg/l and below.
** The flow rate must be checked at the end of the drain line.
***For the correct selection of the filter, use the operating capacity and pressure drop. Long-term operation at flows higher than those tested (more than 30 l/min) may lead to a decrease in cleaning efficiency.